{"title":"T1 (B) viršįtampių ribotuvai","description":null,"products":[{"product_id":"voltage-virsitampiu-ribotuvas-vlb12-275-1p-b","title":"VOLTAGE Surge arrester VLB12-275\/1P B","description":"\u003cp\u003e\u003cstrong\u003eVLB12-275\/1P\u003c\/strong\u003e – T1 (B) surge arrester for single-phase systems at the building's main input. It helps protect electrical installations and connected equipment from lightning-induced and switching impulse overvoltages.\u003c\/p\u003e\u003ch3\u003eKey Advantages\u003c\/h3\u003e\u003cul\u003e\n\n\u003cli\u003eReplaceable protection modules.\u003c\/li\u003e\n\n\u003cli\u003eClear operational status indication, where provided in the model.\u003c\/li\u003e\n\n\u003cli\u003eMounts on a standard 35 mm DIN rail.\u003c\/li\u003e\n\n\u003cli\u003eSuitable for electrical panels in residential, commercial, and industrial facilities.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMaximum Continuous Operating Voltage Uc\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e275 V AC\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eImpulse Discharge Current Iimp (10\/350 µs)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e12.5 kA\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNominal Discharge Current In (8\/20 µs)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e15 kA\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMaximum Discharge Current Imax (8\/20 µs)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e50 kA\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eVoltage Protection Level Up\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e≤ 1.8 kV\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e1P\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eT1 (B)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eDegree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eIP20\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e35 mm DIN rail\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eIEC\/EN 61643-11\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003csmall\u003eInstallation and selection of the protection device must be performed by a qualified electrician, taking into account the electrical network diagram, grounding system, and manufacturer's requirements.\u003c\/small\u003e\u003c\/p\u003e","brand":"VOLTAGE","offers":[{"title":"Default Title","offer_id":65122301870429,"sku":"11001","price":28.99,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1043\/8875\/5805\/files\/vlb12.1P.png?v=1783940901"},{"product_id":"voltage-virsitampiu-ribotuvas-vlb12-5-275-3p-b","title":"VOLTAGE Surge arrester VLB12-275\/3P B","description":"\u003cp\u003e\u003cstrong\u003eVLB12-275\/3P\u003c\/strong\u003e – T1 (B) surge arrester designed for three-phase TN-C systems at the building's main input. It helps protect electrical installations and connected equipment from lightning-induced and switching impulse overvoltages.\u003c\/p\u003e\n\u003ch3\u003eKey advantages\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003eReplaceable protection modules.\u003c\/li\u003e\n\n\u003cli\u003eClear operational status indication, where provided in the model.\u003c\/li\u003e\n\n\u003cli\u003eMounts on a standard 35 mm DIN rail.\u003c\/li\u003e\n\n\u003cli\u003eSuitable for electrical panels in residential, commercial, and industrial facilities.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMaximum continuous operating voltage Uc\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e275 V AC\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eImpulse discharge current Iimp (10\/350 µs)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e12.5 kA\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNominal discharge current In (8\/20 µs)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e15 kA\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMaximum discharge current Imax (8\/20 µs)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e50 kA\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eVoltage protection level Up\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e≤ 1.8 kV\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e3P\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eProtection class\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eT1 (B)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eDegree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eIP20\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e35 mm DIN rail\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eIEC\/EN 61643-11\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\n\n\n\u003c\/table\u003e\n\u003cp\u003e\u003csmall\u003eInstallation and selection of the protective device must be performed by a qualified electrician, taking into account the electrical network diagram, grounding system, and manufacturer's requirements.\u003c\/small\u003e\u003c\/p\u003e","brand":"VOLTAGE","offers":[{"title":"Default Title","offer_id":65122301935965,"sku":"11003","price":79.99,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1043\/8875\/5805\/files\/vlb12_3P.png?v=1783938616"},{"product_id":"voltage-virsitampiu-ribotuvas-vlb12-275-4p-b","title":"VOLTAGE Surge arrester VLB12-275\/4P B","description":"\u003cp\u003e\u003cstrong\u003eVLB12-275\/4P\u003c\/strong\u003e – T1 (B) surge arrester, designed for three-phase TN-S \/ TT systems at the building's main entrance. It helps protect electrical installations and connected equipment from lightning-induced and switching impulse overvoltages.\u003c\/p\u003e\u003ch3\u003eKey advantages\u003c\/h3\u003e\u003cul\u003e\n\n\u003cli\u003eReplaceable protection modules.\u003c\/li\u003e\n\n\u003cli\u003eClear operational status indication, where provided in the model.\u003c\/li\u003e\n\n\u003cli\u003eMounts on a standard 35 mm DIN rail.\u003c\/li\u003e\n\n\u003cli\u003eSuitable for electrical panels in residential, commercial, and industrial facilities.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMaximum continuous operating voltage Uc\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e275 V AC\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eImpulse discharge current Iimp (10\/350 µs)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e12.5 kA\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNominal discharge current In (8\/20 µs)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e15 kA\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMaximum discharge current Imax (8\/20 µs)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e50 kA\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eProtection level Up\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e≤ 1.8 kV\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e4P\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eProtection class\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eT1 (B)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eDegree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eIP20\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e35 mm DIN rail\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eIEC\/EN 61643-11\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003csmall\u003eInstallation and selection of the protective device must be performed by a qualified electrician, taking into account the electrical network diagram, grounding system, and manufacturer's requirements.\u003c\/small\u003e\u003c\/p\u003e","brand":"VOLTAGE","offers":[{"title":"Default Title","offer_id":65122301968733,"sku":"11004","price":99.99,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1043\/8875\/5805\/files\/vlb12.4P.png?v=1783940856"},{"product_id":"voltage-voltage-virsitampiu-ribotuvas-vlbc12-275-4p-iimp-12-5ka-b-pakopa-t1","title":"VOLTAGE surge arrester VLBC12-275\/4P B","description":"\u003cp\u003e\u003cstrong\u003eVLBC12-275\/4P\u003c\/strong\u003e – T1 (B) surge arrester designed for three-phase electrical systems at the building's main entrance. It helps protect electrical installations and connected equipment from lightning-induced and switching impulse overvoltages.\u003c\/p\u003e\u003ch3\u003eKey advantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eReplaceable protection modules.\u003c\/li\u003e\n\u003cli\u003eClear operational status indication, where provided in the model.\u003c\/li\u003e\n\u003cli\u003eMounts on a standard 35 mm DIN rail.\u003c\/li\u003e\n\u003cli\u003eSuitable for electrical panels in residential, commercial, and industrial facilities.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum continuous operating voltage Uc\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e275 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpulse discharge current Iimp (10\/350 µs)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.5 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal discharge current In (8\/20 µs)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum discharge current Imax (8\/20 µs)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage protection level Up\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 1.8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eT1 (B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDegree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61643-11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003csmall\u003eInstallation and selection of the protective device must be carried out by a qualified electrician, taking into account the electrical network diagram, grounding system, and manufacturer's requirements.\u003c\/small\u003e\u003c\/p\u003e","brand":"VOLTAGE","offers":[{"title":"Default Title","offer_id":65122302591325,"sku":"11044","price":99.99,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1043\/8875\/5805\/files\/vlbc12.4P.png?v=1783939553"},{"product_id":"leitai-virsitampiu-ribotuvas-ltd4-b100-1p","title":"LEITAI surge arrester LTD4-B100\/1P","description":"\u003cp data-start=\"2132\" data-end=\"2464\" class=\"PDq2pG_selectionAnchorContainer\"\u003e\u003cstrong data-start=\"2132\" data-end=\"2155\"\u003eLeitai LTD4-B100 1P\u003c\/strong\u003e is a \u003cstrong data-start=\"2162\" data-end=\"2172\"\u003eT1 (B)\u003c\/strong\u003e surge arrester designed to protect single-phase electrical systems from high-energy lightning impulses and switching overvoltages. The device helps protect electrical installations and connected equipment from dangerous overvoltages, thus increasing the reliability and longevity of the electrical system.\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"2466\" data-end=\"2711\"\u003eThe high \u003cstrong data-start=\"2473\" data-end=\"2508\"\u003e100 kA maximum discharge current\u003c\/strong\u003e allows this arrester to be used in facilities requiring reliable primary protection against atmospheric discharges. Its compact design and DIN rail mounting ensure quick and convenient installation.\u003c\/p\u003e\n\u003ch3 data-section-id=\"17bkv0n\" data-start=\"2713\" data-end=\"2740\"\u003eKey advantages\u003c\/h3\u003e\n\u003cul data-start=\"2741\" data-end=\"2981\"\u003e\n\n\u003cli data-section-id=\"bym9bm\" data-start=\"2741\" data-end=\"2794\"\u003eT1 (B) protection against high-energy lightning impulses.\u003c\/li\u003e\n\n\u003cli data-section-id=\"1ixy0er\" data-start=\"2795\" data-end=\"2824\"\u003eReplaceable protection modules.\u003c\/li\u003e\n\n\u003cli data-section-id=\"13khgvk\" data-start=\"2825\" data-end=\"2860\"\u003eClear operational status indication.\u003c\/li\u003e\n\n\u003cli data-section-id=\"n68m7t\" data-start=\"2861\" data-end=\"2910\"\u003eMounts on a standard 35 mm DIN rail.\u003c\/li\u003e\n\n\u003cli data-section-id=\"24vpau\" data-start=\"2911\" data-end=\"2981\"\u003eSuitable for electrical panels in residential, commercial, and industrial facilities.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"dct3ps\" data-start=\"2983\" data-end=\"3013\"\u003eTechnical specifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\n\u003ctable data-start=\"3015\" data-end=\"3322\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\n\u003cthead data-start=\"3015\" data-end=\"3039\"\u003e\n\n\u003ctr data-start=\"3015\" data-end=\"3039\"\u003e\n\n\u003cth data-start=\"3015\" data-end=\"3028\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\n\u003cth data-start=\"3028\" data-end=\"3039\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eValue\u003c\/th\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/thead\u003e\n\n\u003ctbody data-start=\"3065\" data-end=\"3322\"\u003e\n\n\u003ctr data-start=\"3065\" data-end=\"3118\"\u003e\n\n\u003ctd data-start=\"3065\" data-end=\"3106\" data-col-size=\"sm\"\u003eMaximum continuous operating voltage Uc\u003c\/td\u003e\n\n\u003ctd data-col-size=\"sm\" data-start=\"3106\" data-end=\"3118\"\u003e385 V AC\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-start=\"3119\" data-end=\"3172\"\u003e\n\n\u003ctd data-start=\"3119\" data-end=\"3162\" data-col-size=\"sm\"\u003eMaximum discharge current Imax (8\/20 µs)\u003c\/td\u003e\n\n\u003ctd data-col-size=\"sm\" data-start=\"3162\" data-end=\"3172\"\u003e100 kA\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-start=\"3173\" data-end=\"3196\"\u003e\n\n\u003ctd data-start=\"3173\" data-end=\"3190\" data-col-size=\"sm\"\u003eNumber of poles\u003c\/td\u003e\n\n\u003ctd data-start=\"3190\" data-end=\"3196\" data-col-size=\"sm\"\u003e1P\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-start=\"3197\" data-end=\"3225\"\u003e\n\n\u003ctd data-start=\"3197\" data-end=\"3214\" data-col-size=\"sm\"\u003eProtection class\u003c\/td\u003e\n\n\u003ctd data-start=\"3214\" data-end=\"3225\" data-col-size=\"sm\"\u003eT1 (B)*\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-start=\"3226\" data-end=\"3254\"\u003e\n\n\u003ctd data-start=\"3226\" data-end=\"3246\" data-col-size=\"sm\"\u003eDegree of protection\u003c\/td\u003e\n\n\u003ctd data-col-size=\"sm\" data-start=\"3246\" data-end=\"3254\"\u003eIP20\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-start=\"3255\" data-end=\"3289\"\u003e\n\n\u003ctd data-start=\"3255\" data-end=\"3268\" data-col-size=\"sm\"\u003eMounting\u003c\/td\u003e\n\n\u003ctd data-start=\"3268\" data-end=\"3289\" data-col-size=\"sm\"\u003e35 mm DIN rail\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-start=\"3290\" data-end=\"3322\"\u003e\n\n\u003ctd data-start=\"3290\" data-end=\"3303\" data-col-size=\"sm\"\u003eStandard\u003c\/td\u003e\n\n\u003ctd data-start=\"3303\" data-end=\"3322\" data-col-size=\"sm\"\u003eIEC\/EN 61643-11\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\n\n\n\u003c\/table\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\u003cblockquote data-start=\"3324\" data-end=\"3494\"\u003e\n\n\u003cp data-start=\"3326\" data-end=\"3494\"\u003e\u003cstrong data-start=\"3326\" data-end=\"3494\"\u003eInstallation and selection of the surge protective device must be performed by a qualified electrician, taking into account the electrical network diagram, grounding system, and manufacturer's requirements.\u003c\/strong\u003e\u003c\/p\u003e\n\n\n\u003c\/blockquote\u003e","brand":"Transela LT","offers":[{"title":"Default Title","offer_id":65314220441949,"sku":null,"price":99.99,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1043\/8875\/5805\/files\/ltd4-100.png?v=1784632066"}],"url":"https:\/\/transelalt.lt\/en\/collections\/t1-b-virsitampiu-ribotuvai.oembed","provider":"Transela LT","version":"1.0","type":"link"}